Compatibility Tests

The methods used in compatibility tests should include those that will demostrate ABO and RhD incompatibility and detect clinically significant unexpected antibodies

DiaClon ABD-Confirmation for Patients

DiaClon ABD-Confirmation for Patients

The ID-Card DiaClon ABD-Confirmation for Patients can be used for the ABO/RhD blood group control of patients. Current recommendations for RhD typing suggest that, for transfusion recipients and antenatal patients, anti-D reagents should not detect the DVI phenotype. Individuals possessing the DVI phenotype may produce an anti-D to the missing epitopes after immunization by fetal or transfused RhD positive cells. To ensure that appropriate therapeutic measures are instigated, a DVI patient’s red cells should be assigned RhD negative status. Conversely, donor bloods should be tested with anti-D that does detect DVI and assigned RhD positive status, to avoid the unit being transfused to an RhD negative or partial-D patient.

ID-Card (Id-n°: 50053):
•Configuration: A, B, DVI-/A, B, DVI-
•Cell lines: A: LM297/628 (LA-2), B: LM306/686 (LB-2), D: TH28, RUM-1, LDM1

Ordering information

Pkg. size Profiles or single test REF
4 x 12 96 profiles 001254
24 x 12 576 profiles 001257
60 x 12 1440 profiles 001256
112 x 12 2688 profiles 001255

DiaClon ABD-Confirmation for Donors

DiaClon ABD-Confirmation for Donors

DiaClon ABD-Confirmation for Donors is used for the ABO/RhD blood group control of donors. Current recommendations for RhD typing suggest that, for transfusion recipients and antenatal patients, anti-D reagents should not detect the DVI phenotype. Individuals possessing the DVI phenotype may produce an anti-D to the missing epitopes after immunization by fetal or transfused RhD positive cells. To ensure that appropriate therapeutic measures are instigated, a DVI patient’s red cells should be assigned RhD negative status. Conversely, donor bloods should be tested with anti-D that does detect DVI and assigned RhD positive status, to avoid the unit being transfused to an RhD negative or partial-D patient.

ID-Card (Id-n°: 51051):
•Configuration: A, B, DVI+/A, B, DVI+
•Cell lines: A: LM297/628 (LA-2), B: LM306/686 (LB-2), D: ESD-1M, 175-2

Ordering information

Pkg. size Profiles or single test REF
4 x 12 96 profiles 001134
24 x 12 576 profiles 001133
60 x 12 1440 profiles 001136
112 x 12 2688 profiles 001135

ABD-Confirmation

ABD-Confirmation

To ensure that appropriate therapeutic measures are instigated, a DVI patient’s red cells should be assigned Rh negative status. Conversely, donor blood should be tested with anti-D that detects DVI, and assigned Rh positive status, to avoid the unit being transfused to an RhD negative or partial-D patient.

For the examination of previous transfusion records for the recipient’s serological history.

The results from the current testing must be compared with the interpretation of the previously determined blood group.

ID-Card (Id-n°: 50041):
•Human
•Configuration: A, B, D/A, B, D

Ordering information

Pkg. size Profiles or single test REF
4 x 12 96 profiles 001114
24 x 12 576 profiles 001117
60 x 12 1440 profiles 001116
112 x 12 2688 profiles 001115

LISS/Coombs

LISS/Coombs

The methods used in compatibility tests should include those that will demonstrate ABO and RhD incompatibility and detect clinically significant unexpected antibodies. The LISS/Coombs ID-Card allows major crossmatch test by the Indirect Antihumanglobulin test (IAT), and Autocontrol (IAT test).

ID-Card (Id-n°: 50531):
•Available in a selection of package sizes
•Configuration: 6 x AHG (Anti-IgG + C3d) tests, C3d: cell line C139-9

Ordering information

Pkg. size Profiles or single test REF
4 x 12 288 profiles 004014
24 x 12 1728 profiles 004017
60 x 12 4320 profiles 004016
112 x 12 8064 profiles 004015

Coombs Anti-IgG

Coombs Anti-IgG

The ID-Card Coombs Anti-IgG consists of 6 microtubes containing anti-human globulin anti-IgG (rabbit), within the gel matrix.

ID-Card (Id-n°: 50540):
•Configuration: 6 x AHG (Anti-IgG), rabbit

Ordering information

Pkg. size Profiles or single test REF
4 x 12 288 tests 004024
24 x 12 1728 tests 004027
60 x 12 4320 tests 004026
112 x 12 8064 tests 004025

NaCl, Enzyme Test and Cold Agglutinins

NaCl, Enzyme Test and Cold Agglutinins

The ID-Card NaCl, Enzyme Test and Cold Agglutinins is suitable for antibody screening and identification procedures, compatibility testing and reverse grouping.

It is not considered necessary to include the room temperature saline test in routine antibody screening procedures, but the saline test at 4°C can be used to detect cold agglutinins.

ID-Card (Id-n°: 50520):
•Available in a selection of package sizes
•Configuration: 6 tests

Ordering information

Pkg. size Profiles or single test REF
4 x 12 288 tests 005014
24 x 12 1728 tests 005017
60 x 12 4320 tests 005016
112 x 12 8064 tests 005015

DiaClon Complete Crossmatch

DiaClon Complete Crossmatch

The methods used in compatibility tests should include those that will demonstrate ABO and RhD incompatibility and detect clinically significant unexpected antibodies. The ID-Card DiaClon Complete Crossmatch is configured to meet the above requirements in one easy step. It allows for ABD-confirmation of both donor and recipient, major crossmatch test by the Indirect Antihumanglobulin test (IAT), major enzyme crossmatch test, and Autocontrol (IAT test).

ID-Card (Id-n°: 50601):
•Configuration: A, B, DVI-/Enz./2 x AHG
•Cell lines: A: LM297/628 (LA-2), B: LM306/686 (LB-2),
D: LHM59/20 (LDM3), 175-2, AHG: rabbit, C3d: cell line C139-9

Ordering information

Pkg. size Profiles or single test REF
4 x 12 48 profiles 004614
24 x 12 288 profiles 004617
60 x 12 720 profiles 004616
112 x 12 1344 profiles 004615

Complete Crossmatch

Complete Crossmatch

The methods used in compatibility tests should include those that will demonstrate ABO and RhD incompatibility and detect clinically significant, unexpected antibodies. The ID-Card Complete Crossmatch is configured to meet the above requirements in one easy step:
– ABD-confirmation of both donor and recipient
– Major crossmatch test by the Indirect Antihumanglobulin test (IAT)
– Major enzyme crossmatch test
– Autocontrol (IAT test)

ID-Card (Id-n°: 50591):
•Configuration: A, B, D/Enz./2 x AHG,
•Anti-A, Anti-B and Anti-D: human, AHG: rabbit, C3d: cell line C139-9

Ordering information

Pkg. size Profiles or single test REF
4 x 12 48 profiles 004604
24 x 12 288 profiles 004607
60 x 12 720 profiles 004606
112 x 12 1344 profiles 004605